Abstract:
The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D printing of occlusal splints, as well as to evaluate the differences in wear and surface hardness between rigid and flexible 3D-printed occlusal splint materials. Two-body wear and Vickers hardness tests were performed. The vertical wear depth and Vickers hardness values were statistically analyzed. Vertical wear depth and surface hardness values were statistically significant among the investigated materials (p<0.05). The lowest vertical wear depth was observed for the heat-cured resin (27.5±2.4 ?m), PMMA-based milled material (30.5±2.8 ?m), and autopolymerizing resin (36.7±6.3 ?m), with no statistical difference (p<0.05).
Flexible 3D-printed and CAD-CAM milled polycarbonate-based splint materials displayed lower surface hardness and higher wear than the PMMA-based materials. PMMA-based splint materials displayed the most consistent surface hardness and wear resistance regardless of the manufacturing technology.
Resumen:
El objetivo de este estudio in vitro fue evaluar el desgaste y la dureza superficial de nueve materiales para la fabricación convencional, fresado sustractivo e impresión 3D de férulas oclusales, así como para evaluar las diferencias en el desgaste y la dureza de la superficie entre Materiales rígidos y flexibles para férulas oclusales impresas en 3D. Se realizaron pruebas de desgaste de dos cuerpos y dureza Vickers.
Se analizaron estadísticamente los valores de profundidad y dureza Vickers. Los valores de profundidad de desgaste vertical y dureza superficial fueron estadísticamente significativa entre los materiales investigados (p<0,05). La profundidad de desgaste vertical más baja se observó para la resina termocurada (27,5 ± 2,4?m), material molido a base de PMMA (30,5±2,8 ?m) y resina autopolimerizable (36,7±6,3 ?m), sin diferencia estadística (p<0,05). Los materiales flexibles para férulas a base de policarbonato impresos en 3D y fresados con CAD-CAM mostraron una menor dureza superficial y un mayor desgaste que los materiales basados en PMMA. Los materiales para férulas a base de PMMA mostraron la dureza superficial y la resistencia al desgaste más consistentes independientemente de la tecnología de fabricación.
Citación recomendada (normas APA)
Mona; Perea Mosquera Gibreel, "Two-body wear and surface hardness of occlusal splint materials = Desgaste de dos cuerpos y dureza superficial de los materiales de férulas oclusales", Colombia:Dental Materials Journal, 2022. Consultado en línea en la Biblioteca Digital de Bogotá (https://www.bibliotecadigitaldebogota.gov.co/resources/3711938/), el día 2025-05-06.